To replace pump tubes, you replace the entire pump "cassette" in the printer.
Replacement cassettes are supplied in the printer Start-up Kit. Additional
cassettes can be ordered from your Stratasys service provider.
To replace the waste pump tubes:
1. Make sure that the printer is in Idle mode (see the figure on page 4-4).
Note:
The printer enters Idle mode about 16 minutes after printing stops. To
force the printer into Idle mode, close the printer application: From the
File
menu, click
Exit
.
2. Using an 8-mm hex (Allen) key, open the two latches that secure the left
printer panel (as you face the printer).
Figure 4-131 Opening a panel latch
3. Open the panel and disconnect the ground (earth) wire.
Figure 4-132 Ground wire connected to panel
4. Remove the panel.