Stratasys J750/J735/J720 User Guide
4 Operating and Maintaining the Printer
DOC-08040 Rev. R
4-94
2. Close the printer application.
3. Shut down the printer computer, wait 60 seconds after the monitor goes
blank, and turn off the main power switch.
Caution:
The monitor goes blank as soon as the remote desktop link terminates—
before computer shutdown. Turning off the printer before computer shutdown
can cause damage.
4. Using an 8-mm hex (Allen) key, open the latches that secure the back of the
materials cabinet and remove the back of the cabinet.
5. Locate the 10-micron filters, installed for the relevant material.
Figure 4-139 Material filters installed
6. Put on protective gloves.
Warning: Toxic and Corrosive Materials
Prolonged contact with resins could cause skin irritation. Put on protective
gloves before continuing.
7. Disconnect the tube connected to the
top
(inlet) side of the material filter.
8. Make sure that the fitting at the end of the feed-tube remains attached to the
tube. Re-attach it, if necessary.
9. Cover the filter with a cleaning cloth (or paper towels) to absorb material
spillage.