6-3
764333-268
22. Display shows
BACK D MAX
. Lower back
section to maximum position and press
REV.
ORIENT
button to save setting.
23. Display shows
BACK U MAX
. Raise back section
to maximum position and press
REV. ORIENT
button to save setting.
24. Display shows
SLIDE H MAX
. Use
BACK
DOWN
button to return table to center. Do not
use
LEVEL
button.
25. Slide tabletop to maximum head position then
press
REV. ORIENT
button to save setting.
26. Display shows
SLIDE F MAX
. Slide tabletop to
maximum foot position then press
REV. ORIENT
button to save setting. Slide should hesitate
momentarily at zero position.
27. Display shows
TABLE D MAX
. Lower tabletop
to lowest position then press
REV. ORIENT
button to save setting.
28. Display shows
TABLE U MAX
. Raise tabletop to
highest position then press
REV. ORIENT
button
to save setting.
29. Display shows
RESET ALARM
. Press
REV.
ORIENT
button to reset all sensor alarms.
NOTE: Calibration data is lost if you fail to press
REV. ORIENT
button in this step.
Important:
Do not press the
LEVEL
button until
Step 31
is performed.
30. Hand Control exits ADJUST MODE.
31. Press
OFF
button on Primary Hand Control to
turn power OFF then press any button (but
OFF
)
to return power to table.
32. Verify table returns to level correctly from all
positions, including Flex and Reflex.
33. Verify all ALS functions.
6.3.2 Newer Control Board (P150832-769)
1. Plug table into appropriate facility outlet.
2. Press any primary hand control button to turn table
ON.
3. Engage floor locks.
4. Ensure leg section is attached to table.
5. Raise table high enough to get a full leg down
articulation without hitting table base.
6. Simultaneously press and release
LEVEL
and
REV.
ORIENT
buttons.
7. Display shows
ADJUST MODE
.
NOTE: During table sensor calibration, note the
following:
1) The
REV. ORIENT
LED must be OFF.
2) Do not press
LEVEL
button during procedure
or control exits Calibration Mode
without
storing the values.
3) Pressing
FLOOR LOCK
button during
procedure orders the control to skip displayed
articulation. This is NOT recommended during
a final calibration.
8. If
ADJUST MODE
does not display or
REV.
ORIENT
LED is ON, turn Hand Control
OFF
then
ON
and repeat
Step 6
until correct results appear.
9. Press
REV. ORIENT
button, display shows
LEVEL
ADJ
.
10. Using a level, position tabletop (starting with seat
section) so all sections are level in both horizontal
directions.
11. Slide tabletop until it is approximately 3/16"
(4.8 mm) past foot end of tilt frame (see Figure 6-1).
This is known as “Zero Slide” position.
12. Press
REV. ORIENT
button to save setting.
13. With display showing
SLIDE F MAX
, slide
tabletop to maximum foot end position.
14. Press
REV. ORIENT
button to save setting.
15. Display shows
SLIDE H MAX
. Slide tabletop
maximum head end position.
16. Press
REV. ORIENT
button to save setting.
Display shows
TABLE D MAX
.
17. Use Slide Foot button to return table to center. Do
not use
LEVEL
button.
18. With display showing
TABLE D MAX
, lower
table to maximum down position.
19. Press
REV. ORIENT
button to save setting.
20. Display shows
TABLE U MAX
. Raise table to
maximum up position.
21. Press
REV. ORIENT
button to save setting.
Display shows
R TREND MAX
.
22. Use
HEIGHT DN
button to return table to near
middle height. Do not use
LEVEL
button.
23. With display showing
R TREND MAX
, reverse
trendelenburg tabletop to maximum reverse
trendelenburg position.
24. Press
REV. ORIENT
button to save setting.
25. Display shows
TREND MAX
. Trendelenburg to
maximum trendelenburg position.
Summary of Contents for Cmax
Page 1: ......
Page 4: ......
Page 65: ......
Page 142: ...Page 3 of 14 ...
Page 148: ...Page 9 of 14 ...
Page 149: ...Page 10 of 14 ...
Page 155: ...Page 2 of 2 Figure 1 Second Spacer ...
Page 164: ......
Page 211: ......
Page 212: ......
Page 213: ......
Page 214: ......
Page 215: ......
Page 216: ......
Page 217: ......