6-22
122993-622
Operator Manual
Routine Maintenance
Pump motor must be lubricated once a year. When necessary, grease can be
completely renewed by forcing out old grease with new grease.
1.
If possible, place a pan under motor to catch old grease.
NOTE: Motor should be lubricated while warm.
2.
Thoroughly wipe off housing around fill and drain plugs.
3.
Remove fill and drain plugs (see Figure 6-12). Clear drain hole of any
hardened grease which may have accumulated.
NOTE: Depending on model and year of pump, motor may be equipped with
one or two grease fittings. If motor is not provided with grease fittings, no
lubrication is necessary.
4.
Using a low pressure grease gun, add recommended grease through fill
hole until it starts to come out of drain hole.
NOTE: Use only fresh, uncontaminated lubricant.
5.
Run motor for ten to twenty minutes to expel any excess grease.
6.
Thoroughly clean the fill and drain plugs before replacing them.
6.16 Lubricate
Pump Motor
Figure 6-12. Lubricate Pump Motor
Fill Plug
Drain Plug
WARNING – BURN HAZ-
ARD: Pipes may be ex-
tremely hot.
W A R N I N G – S L I P P I N G
HAZARD: To avoid slippery
floor conditions, immedi-
ately wipe up any spilled
liquids or drippage. If
spilled liquids or drippage
are detergents or other
chemicals, follow safety
precautions and handling
procedures set forth on
detergent or chemical label
and/or Material Safety Data
Sheet (MSDS).