132
Note
• If this option is activated, on the
AVP the
Building automation
icon
will be additionally displayed on the
AVP start page. The user interface
of the building automation server is
accessed by tapping on the icon.
17
The
URL building automation:
input box is shown.
18
In the
URL building auto
-
mation:
input box, enter the URL
address of the building automa
-
tion server in the provided form
(http://[IP address]:8080) (e.g.
http://192.168.1.10:8080).
Note
• The building automation server
(JUNG Facility Pilot Server) is not a
system component of the Siedle
Access system. Integration / display
of the user interface takes place
using the embedded HTML frame.
For commissioning and operation,
please use the relevant manufacturer
documentation.
19
Set the
ringtone volume
in
accordance with the assumed
ambient volume using the slide con
-
troller at the hardware terminal (high
volume for loud environments).
20
Set the
voice volume
in accord
-
ance with the assumed ambient
volume using the slide controller at
the door station (high volume for
loud environments).
Note
• For optimum setting of the ring
-
tone volume and the voice volume,
you may have to carry out several
tests during function testing.
21
Activate/deactivate the option
Show time at terminal
, if you wish
the system time at the Access server
to be displayed (
Yes
) nor not (
No
)
(default setting:
Yes
).
22
Leave the selection
Default
telephone script
unchanged under
Telephone script
if you do not wish
a secondary signal unit or a surveil
-
lance camera to be operated at this
door/door station. Otherwise select
the required telephone script.
23
Change to the area
Button con-
figuration
.
Note
• Instead of mechanical buttons, at
the AVP there is a touch panel, in
which a large number of tiles with
a large selection of wide-ranging
different functions, inscriptions and
icons can be configured using the
Access system. The configurable
functional scope is the same as for
the previously configured hardware
terminals.
24
Inscribe the required number of
tiles with a meaningful inscription
matching the used functions.
25
For each tile you wish to con
-
figure, select the right icon/symbol
in accordance with the overview
Use
of symbols – AVP
:
26
Configure each of the
Tiles
of
the hardware terminal with one of
the offered functions (
No action
,
Device call
,
User call
,
Group call
,
External call
,
Rerouting to device
/
User
/
Group
/
External
or
Scripts
and switching functions
), in
accordance with the configuration
parameters and instructions on the
previous pages.
27
Change to the area
Switching
outputs/inputs
.
28
At the output, define the
required application (
No action
,
Free switching time
) and configure
it in accordance with the configu
-
ration parameters described in the
previous pages.
29
At the input, define the required
application (
No action
,
Switching
point
or
Signal status
) and con
-
figure it in accordance with the
configuration parameters described
in the previous pages.
30
Click on
Save
to take the
changes over in the system.
31
Configure each
AVP
using the
same procedure.
Configure devices
AVP 870-…