128
Switching outputs/inputs
Each of the Access indoor stations
(AHF, AHFV, AHT, AHTV, AVP) is
assigned a switching input and
a switching output. Optionally,
an Access indoor station can be
upgraded with the Access Input/
Output accessory
AZIO 870-0
to
include an additional input and
output. A connected AZIO is also
shown here and can be configured
via this user interface.
Procedure –
Button configuration
with switching point
1
In the navigation area, click on the
Users
menu.
2
The
Users
menu opens up.
3
In the folder/project structure,
click into the required Access indoor
station.
4
The page
Edit device: [device
name]
opens in the content area.
5
In the
Button configuration
area, select the function
Scripts and
switching functions
for one of the
buttons.
6
Select
Switching point
.
Note:
If other parameters have to
be configured for a particular button
assignment (e.g. with one switching
point), the
Set
button becomes
active.
After clicking on
Set
, a dialogue
is displayed in which the relevant
required data can be selected or
entered.
7
Click on
Setting
.
8
In the
Setting
dialogue, select the
switching output (e.g. Mr. Maier:
Output 1).
9
Click on
Save
to save your selec
-
tion.
10
Click on
Save
to take the
changes over in the system.
11
Carry out a function test.
Procedure –
Configuring the
Siedle indoor stations AHF, AHFV,
AHT, AHTV
1
Connect the server hardware to
the Access network.
2
In the navigation area, click on the
Users
menu.
3
The
Users
menu opens up.
4
Click in the navigation area in the
opened
Users
menu on the folder
Not assigned devices
, in order to
open it.
5
The folder
Not assigned devices
is opened in the navigation area.
6
The hardware terminal is displayed
following detection by the Access
system in the menu
Users > Not
assigned devices
.
7
Drag&Drop the still unassigned
hardware terminals using the mouse
from the folder
Not assigned
devices
to the required position of
the
Project/folder structure
.
8
Click on the hardware terminal.
9
The page
Edit device: [name of
the hardware terminal]
opens up
in the content area.
10
Carry out all inputs in the
General
area.
11
Always assign meaningful names
and descriptions.
Note
• The fields
Call number
and
Assignment
are automatically
issued by the Access system and can
be edited at any time.
12
Check the
Call number
and
change it if required, for example to
implement your call number system.
13
Check the
Assignment
and
change/supplement it if required.
14
Leave the entered
MAC address
unchanged and change to the next
field.
15
Only with AHF/AHFV:
Define
the mounting method,
Wall
or
Table
.
16
The
hardware revision
is an
information field and cannot be
edited.
17
Set the
ringtone volume
in
accordance with the assumed
ambient volume using the slide con
-
troller at the hardware terminal (high
volume for loud environments).
18
Set the
voice volume
in accord
-
ance with the assumed ambient
volume using the slide controller at
the door station (high volume for
loud environments).
Note
• For optimum setting of the ring
-
tone volume and the voice volume,
you may have to carry out several
tests during function testing.
19
Activate/deactivate the option
Show time at terminal
, if you wish
the system time at the Access server
to be displayed (
Yes
) nor not (
No
)
(default setting:
Yes
).
20
Leave the selection
Default
telephone script
unchanged under
Telephone script
if you do not wish
a secondary signal unit or a surveil
-
lance camera to be operated at this
door/door station. Otherwise select
the required telephone script.
21
Change to the area
Button con-
figuration
.
Configure devices
AHF/AHFV/AHT/AHTV 870-…