Chapter 11: ATM Cards
ATM ARP Parameters
SmartBits System Reference
159
•
Initialization Method
.
–
Normal
– This is the default initialization method, where the LEC on the ATM
SmartCard attempts to contact the LECS at the default address specified by the
ATM Forum to obtain addressing information of the LES and BUS.
•
Other Possible Initialization Methods
:
–
LECS Direct –
Allows you to directly input the ATM address of the LECS. This is
to be used if LECS does not reside at the default address specified by the ATM
Forum.
–
LES Direct – Allows you to input the ATM address of the LES. This method can
be used when no LECS service is available and the LES's ATM address is known.
•
ELAN Type
. Only LANE 802.3 is currently supported.
•
ELAN MTU
. Specify the Maximum Transmission Unit of this ELAN.
•
ARP Retry Count
. Number of ARP retries to attempt before giving up.
•
Expected ARP Reps. Time
. Amount of time to wait before retrying to send another
LE_ARP or expiring (time out).
ATM ARP Parameters
Applications
Supported:
SmartWindow, SmartLib.
Card Types:
All ATM Cards.
Use the ATM ARP tab to specify the parameters (ARP Server ATM Address, ARP Client
IP Address, Inter ARP Gap, Inter Call Gap, ARP Retries).
To connect to the ATM ARP server. In order to establish a connection from the SmartCard
to the ATM ARP Server, you must ensure that:
•
LMI
is up or has already obtained the ATM address of the SmartCard.
•
SCOP/UNI
must be running (i.e. SSCOP in "Data Transfer Ready State", and SAAL
in "Connected" state).
Summary of Contents for SmartBits System
Page 8: ...viii SmartBits System Reference ...
Page 58: ...50 SmartBits System Reference ...
Page 82: ...74 SmartBits System Reference ...
Page 88: ...80 SmartBits System Reference ...
Page 196: ...188 SmartBits System Reference ...
Page 202: ...194 SmartBits System Reference ...
Page 218: ...210 SmartBits System Reference ...
Page 238: ...230 SmartBits System Reference ...
Page 278: ......