Chapter 9: Ethernet Cards
Standard Ethernet Features
SmartBits System Reference
121
Filters
Pre-capture filtering is available on one or more of the following criteria: CRC, alignment,
oversize, undersize, data integrity errors, Rx triggers, or All.
Flow Control
Supports flow control (PAUSE frames) according to the IEEE 802.3x standard. On the
receiver side, each port detects PAUSE frames as they are received and optionally initiates
the proper throttling of the transmitter. Additionally, each port supports a counter that
indicates the number of PAUSE frames received.
Frame Rates, Maximum
How to calculate the maximum frame rate:
•
Constants:
Gap = 96 bits
Preamble = 64 bits
Frame Size = 8
×
N bits (N = number of bytes)
Speed = 10,000,000 (Ethernet), 100,000,000 (Fast Ethernet), 1,000,000,000 (Gigabit
Ethernet) in bits per second (bps)
•
Formula:
Maximum Frame Rate = Speed
÷
(Gap + Pr Frame Size)
Size
Ethernet (pps)
Fast Ethernet (pps)
Gigabit Ethernet (pps)
64
14,880
148,809
1,488,095
128
8,445
84,459
844,594
256
4,528
45,289
452,898
512
2,349
23,496
234,962
1024
1,197
11,973
119,731
1280
961
9,615
96,153
1518
812
8,127
81,274
Summary of Contents for SmartBits System
Page 8: ...viii SmartBits System Reference ...
Page 58: ...50 SmartBits System Reference ...
Page 82: ...74 SmartBits System Reference ...
Page 88: ...80 SmartBits System Reference ...
Page 196: ...188 SmartBits System Reference ...
Page 202: ...194 SmartBits System Reference ...
Page 218: ...210 SmartBits System Reference ...
Page 238: ...230 SmartBits System Reference ...
Page 278: ......