75
TRAK Machine Tools
Southwestern Industries, Inc.
TRAK TMC Mills with ProtoTRAK RMX CNC Safety, Installation, Maintenance, Service & Parts List
5.1.2.1
Programming Panel Replacement
1.
Turn power off to the machine and control.
2.
Remove all cover bolts on the rear of the Pendant except the top two which allow support of the
panel while you remove the remaining bolts. The holes are slotted so you can lift the panel with
the top two bolts in place.
3.
Disconnect the following cables as shown in figure 5.1.2.1:
a.
USB Ports (4) and Audio mounted on the medal pendant casing
b.
DB25 Umbilical cable assembly
c.
4 ribbon cables from RUN PANEL to Programming panel overlay interface board
d.
Both LAN cable assembly
e.
E-stop cable wire assembly
f.
RSG connector remove screws from the bottom of medal pendant casing as shown in
image
Figure 5.1.2.1 - Panel Cabling
4.
Support programming panel from the front and remove the 8 bolts from the programming panel
perimeter and remove the panel from the front of the pendant as shown in figure 5.1.2.1.
5.
Replace programming panel, replace the bolts and tighten just past finger tight, connect the data
wires listed in step 3 and shown in figure 5.1.2.1. Replace rear cover and tighten bolts.
6.
Power up the TMC.
7.