68
TRAK Machine Tools
Southwestern Industries, Inc.
TRAK TMC Mills with ProtoTRAK RMX CNC Safety, Installation, Maintenance, Service & Parts List
Diagnostic Service Codes
Code
Description
Comment
1
Program, file, log, backup
Stores a file to flash drive documenting TMC
operations for debugging uses
54
Continuous Run Mode
Cycles through the program in current memory.
81
Program Panel Keyboard Test
Gives a tone feedback to a button push and
highlights the button.
131
Manual DRO
Turns off servo’s so you can check encoders
132
Electronic Handwheel Test
Test the EHW signals
314
Toggle Test Lights in Status Line
Used to troubleshoot control issues
319
Error Logging
Logs the machine as it runs
320
Fault Log
Error log access
326
Error Message Display
Displays error messages on screen
327
Display Memory Check
Displays memory availability of various devices
521
Check Control/Indexer IO
Launches application to test all system I/Os
522
Diagnostic Charting Tool
Diagnostic used for plotting various inputs
Operator Defaults/Options Service Codes
Code
Description
Comment
79
Turn On Beeper
Turn the beeper on when pressing keys on either
of the front panels
328
EPA On/Off
Enables/Disable EPA section
600
Manager User Profiles
Allows user to define multiple user profiles for
machinists accessed in DEFAULTS section
4.8.1
Section A - Software Code Details
The following codes pertain to software functions in the control. To get to any of these codes go to
Service Codes, press “A” and
press the code you wish to view.
Note -
If you are working with the SWI Customer Service Group, write the values down for Code 33.
These values will be valuable for troubleshooting.
4.8.1.1
Code 33: Software ID
The Code 33 is the software identification procedure. This will most likely be used when a customer
service representative asks to identify what version(s) of software is being run on your machine.
Lube Pump Setup Service Codes
Code
Description
Comment
300
Lube Pump Switch Discharge
Allows the user to manual discharge the lube
pump
301
Set Lube Pump Cycle Time
Sets the time in minutes between pumping cycles
302
Set Lube Pump Discharge Time
Sets the time in seconds for how long to pump
for each cycle.