56
TRAK Machine Tools
Southwestern Industries, Inc.
TRAK TMC Mills with ProtoTRAK RMX CNC Safety, Installation, Maintenance, Service & Parts List
3.3.6
E-Stop Error
The Warning button is flashing and has an E-stop message, error code 261. It will not allow the machine
to be moved around.
Possible Cause
Check This
Make sure E-Stop switch is out and not
pressed
Clear message and make sure Power Reset button is turned
on. If problem persists reboot control and see if message
goes away.
Jumper may have come loose
Check removable jumper is in place and connected properly
as shown below:
If connected, restart TMC.
Computer module internal failure
Make sure both E Stop jumper lights are on. If either is off,
computer module failure, call TRAK for service. If both are
on, more to next step.
Computer module internal failure
Check E-Stop lights in electric cabinet, make sure 2 LEDs
are on as shown below:
Either light off, computer module failure, call TRAK. If both
are on, move to next step.