Chapter 8
Key Frame Effects
8-23
Path settings within an M/E bank or the PGM/PST bank
Making path settings for individual items within an M/E bank or
the PGM/PST bank
For example, in the case of the M/E-1 bank, use the following procedure.
For the M/E-2 and PGM/PST bank, use a corresponding procedure.
1
In the SWER KF PATH menu, press F2 (M/E-1).
The function key indications change as follows.
(F6 (CHR KEY) does not appear for the PGM/PST bank.)
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
CURVE
CHR
KEY
LINEAR
LINEAR
TRANS
LINEAR
LINEAR
LINEAR
KEY1
LINEAR
OFF
KEY2
WIPE
COLOR
BKGD
XPT
DSBL
HUE
PATH
2
Press one of F1 (KEY1) to F6 (CHR KEY) to select the corresponding
curve path type.
Pressing each of F1 to F6 cycles through the settings in the order shown
below. F1 (KEY1), F2 (KEY2), F4 (TRANS), and F6 (CHR KEY) cycle
through four settings excluding “SPLINE”.
OFF
t
STEP
t
LINEAR
t
S-CURVE
t
SPLINE
The selected path type is shown on the menu display by an icon.
3
If you selected “SPLINE” in step
2
, adjust control knobs 1 to 3 as
follows.
4
Press F10 (HUE PATH), then select the HUE path type.
For details, see steps
4
and
5
in the section “Setting the path for all
banks” (page 8-21).
Knob
Parameter
Setting
1
Tension
Degree of tension between points (–4.000 to +4.000)
2
Bias
Degree of inclination of tangent at point (–4.000 to +4.000)
3
Continuity
Degree of continuity at point (–4.000 to +4.000)
Summary of Contents for DVS-7250
Page 10: ......
Page 30: ......
Page 66: ......
Page 67: ...Menu Organization 3 2 Basic Menu Operations 3 6 Chapter 3 Basic Menu Operations ...
Page 274: ......
Page 328: ......
Page 364: ......
Page 488: ......
Page 495: ...Appendixes A 3 Enhanced Wipes 21 23 24 26 27 29 49 300 301 302 303 304 POLYGON ...
Page 534: ......
Page 542: ...Sony Corporation B P Company BZS 7061A WW A AE0 600 01 1 1999 ...