1-21
BRC-300/300P
BRU-300/300P
1-7-3. RM-BR300
n
Never change the settings of the factory use switches.
MD-131 Board
Ref. No.
Bit
Name
Description
Factory setting
S5001
—
POWER ON/OFF
Sets the unit power to ON or OFF.
OFF
S5003
1
RS-232C/RS-422
Selects RS-232C or RS-422.
OFF (RS-232C)
ON:
RS-422
OFF: RS-232C
2
9600bps/38400bps
Sets communication baud rate.
OFF (9600 bps)
ON:
38400 bps
OFF: 9600 bps
3
—
Not used
OFF
4
—
Not used
OFF
S5004
—
TALLY/CONTACT
Selects the function of the TALLY/
CONTACT
CONTACT connector.
(TALLY)
S5005
—
MODE SELECT
Set this switch according to the VISCA
0
correspondence camera to be connected.
S5006
1
ENABLE ON/OFF
Factory use
OFF
2
CPU WR MODE
Set this to ON only when writing the
OFF
firmware.
3
—
Not used
OFF
4
—
Not used
OFF
S5001
S5004
S5005
S5006
MD-131 BOARD (SIDE A)
S5003