2-10
BRC-300/300P
BRU-300/300P
PSW2.6
x
6
Motor plate
Pan motor
PSW.SRW2.5
x
6
PSW.SRW2.5
x
6
2-1-8. Pan Motor
Removing
1.
Remove the base plate. (Refer to Section 1-3-4.)
2.
Remove the SY-314 board.
(Refer to steps 2 to 4 in Section 2-2-11.)
3.
Remove the two screws, and remove the motor plate.
4.
Remove the four screws, and remove the pan motor
from the motor plate.
Installation
5.
Reattach the pan motor in the reverse order from steps
3 and 4.
n
Pay attention not mix up the screws (PSW.SRW2.5
x
6) and the screws (PSW2.6
x
6).
6.
Reassemble the unit in the reverse order from steps 1
and 2.
Installation
8.
Reattach the worm base B, gear press spring and two
holders W3 to a new worm gear assembly (pan).
n
Reattach the worm gear assembly (pan) to the worm
base B with the holders W3 installed as shown in the
figure.
9.
Reattach the worm gear assembly (pan) in the reverse
order from steps 3 to 6.
10. Reassemble the unit in the reverse order from steps 1
and 2.
Holder W3
Worm base B