1-8. Circuit Protection Parts (Fuse)
Each unit equips a fuse as a circuit protection part.
The fuse melts if overcurrent flows or the unit overheats
due to a unit problem.
When replacing the fuse, be sure to use the following
designated parts.
Correct the cause resulting in the melting of the fuse before
replacement.
w
Use Designated Parts
The fuse/IC link is an important part for ensuring safety.
Replacement with parts other than those designated will
result in fire hazards and electric hazards. Therefore be
sure to use only designated parts.
BRC-300/300P
Board
Ref. No.
Part No./Description
SY-314
F1501
!
1-533-998-11
F1502
On-chip fuse 1.0 A, 125V
F1503
!
1-533-483-11
F1504
On-chip fuse 1.6 A, 125V
BRU-300/300P
Board
Ref. No.
Part No./Description
MC-66
F4001
!
1-533-483-11
On-chip fuse 1.6 A, 125V
F4002
!
1-533-998-11
F4003
On-chip fuse 1.0 A, 125V
RM-BR300
Board
Ref. No.
Part No./Description
MD-131
F5001
!
1-533-998-11
On-chip fuse 1.0 A, 125V