Electrical pre-wiring
To motorise your gate:
• Install a 230 V electric supply on one of the gateposts, as near as possible to the SGA
motor.
• Interconnect the gateposts using the 2 x 1
mm
2
cable provided (or two cables for
photocells).
Use a 25-mm-diameter Orange ICT protective sheath for burying the cables.
If you cannot dig a cable trench between the two gateposts, use a raceway that will bear the
weight of vehicles passing over it (ref. 2400484).
• Provide a ducted connection between the two gateposts to wire the photocells.
2
1
3
4
2 3
1
Bracket
Electronic
control unit
Junction box
(not supplied)
2 x 1 mm
2
cable between motors
2 x 0.75 mm
2
cable between cells
2 3
Flexible ICT duct
(
)
Power input from mains: (3 x 1.5 mm
2
)
24-V connection between the two motors
provided: (2 x 1 mm
2
)
2
1
3
4
24-V connection between
the two cells for automatic
operation: (2 x 0.75 mm
2
)
2
1
3
4
l
Mains power
To operate, the gate opener must be powered at 230 V, 50 Hz.
The electrical wire must be:
• Used only for the gate opener.
• Protected:
— by a 10-A fuse or circuit breaker,
— by a differential device (30 mA).
• Installed in compliance with electrical safety standards in force locally.
An all-pole power disconnection means must be provided:
• either a supply cable with an electrical plugt,
• or a switch which keeps the contacts at least 3 mm apart at each pole (see standard EN
60335-1).
It is recommended to install a lightning arrestor (with a maximum residual voltage of 2 kV).
1
2
3
Summary of Contents for SGA 6000
Page 1: ...MOTOR DRIVES FOR LEAF GATES SGA 6000 SGA 6000 INT GRAL SGA 6000 INT GRAL...
Page 3: ......
Page 4: ......
Page 6: ...2 M10 x4 x4 x8 x8 M10 x 150 M6 x 40 M6 HM10 x8 HM6 x4 5 7 8 5 7 8 Not included in the kit...
Page 38: ...34 34 Accessories Description and connections n Section des c bles par type d accessoire TX RX...