25
English English
settings
5
At the end of these 2 steps, the STATUS indicator is continuously lit.
If the STATUS indicator is flashing, refer to the troubleshooting section on page 33.
This must be a full cycle (2 complete and uninterrupted openings/closings). If it is interrupted, the
process is simply postponed, and will resume the next time the gate is opened.
l
Checking that settings are correct
Press the button stored on the remote control.
Press the button again so that both leaves stop midway through their travel.
Cut mains power for at least 5 seconds.
Restore mains power.
Press the button stored again.
the leaves MUst continue in the opening direction.
If the leaf does not open correctly:
•
The leaf which moves first (controlled by M1) starts to close
invert wires BLUE and BROWN on motor M1.
•
The leaf which moves second (controlled by M2) starts to close
invert wires BLUE and BROWN on motor M2.
After inverting the wiring on one or two motors, the leaf travel learning procedure will
have to be carried out again.
5
4
3
2
1
o
Fitting the covers.
Fit the covers on the motors.
2
Screw on the covers.
3
Check that the arms are locked (see page 22).
1
YoUR MotoRs ARE READY to oPERAtE
By default, they operate in sequential mode and opening automatically.
Summary of Contents for SGA 6000
Page 1: ...MOTOR DRIVES FOR LEAF GATES SGA 6000 SGA 6000 INT GRAL SGA 6000 INT GRAL...
Page 3: ......
Page 4: ......
Page 6: ...2 M10 x4 x4 x8 x8 M10 x 150 M6 x 40 M6 HM10 x8 HM6 x4 5 7 8 5 7 8 Not included in the kit...
Page 38: ...34 34 Accessories Description and connections n Section des c bles par type d accessoire TX RX...