29
English
Advanced parameter setting
English
the remote control must be placed on the electronic unit to access the settings
menu.
It is impossible to access the settings menu using a «3-button» remote control.
Do not block the light sensor with the remote control (see page 7).
once you have accessed the settings menu, the parameters can be set
remotely.
The motor parameter setting cannot be carried out when the gate is moving.
Changes to the parameters will be taken into account after the first time the gate is opened.
n
Adding remote controls
n
Entering the settings menu
If you have stored 32 remote controls and you store a 33rd remote control, the first remote
control stored will be deleted and so on.
l
Adding 2- or 4-button remote controls
l
Adding 3-button remote controls
Repeat the operations described in the «Storing the remote controls» section on page 23.
Briefly press the up or down button on the remote control
The RADIO indicator lights up then goes out.
Press the left-hand button on the remote
control until the RADIO indicator lights
up and the
TOTAL+PEDESTRIAN
indicator flashes.
2
2
Place the remote control under the word «Somfy»
Place the «2-button» remote control
under the word «Somfy»
1
1
Added remote controls will have the same mode of operation as remote controls which
have already been stored.
<0,5s
Summary of Contents for SGA 6000
Page 1: ...MOTOR DRIVES FOR LEAF GATES SGA 6000 SGA 6000 INT GRAL SGA 6000 INT GRAL...
Page 3: ......
Page 4: ......
Page 6: ...2 M10 x4 x4 x8 x8 M10 x 150 M6 x 40 M6 HM10 x8 HM6 x4 5 7 8 5 7 8 Not included in the kit...
Page 38: ...34 34 Accessories Description and connections n Section des c bles par type d accessoire TX RX...