The second part of the cleaning requires the complete removal of the moving part of
the equipment. The first thing to do is to disconnect the power cord and the
connections if there is external probe or chrono-thermostat.
We remove the equipment from its fixed base. At the rear of the fixed base, to the left
we have the smoke box that is connected to the chimney. On the front there is a red
silicone gasket that is responsible for making the connection between the extractor and
the smoke box, it must be checked that this gasket is in good condition. The joint can
not have cracks or cuts and must be flexible, if it is not in good condition it is
necessary to replace. The smoke box on the right side has a fixed cover with screws 6
DIN912 M6x12 (see figure 67), it is necessary to remove this cover to gain access to
the inside of the box and clean (see figures 68).
Figure 57
–
Smoke box cover
Inside the box there are two smoke deflectors, positioned as shown in figure 68, to
carry out a proper cleaning it is necessary to remove them.