background image

Model

Serial No.

Date Purchased

SAVE THIS BOOK

This book is valuable. In addition to instructing you
on how to install and maintain your appliance, it also
contains information that will enable you to obtain
replacement parts or optional accessory items when
needed. Keep it with your other important papers.

®

INSTALLATION INSTRUCTIONS

DESA INTERNATIONAL,
2701 INDUSTRIAL DRIVE
P.O. BOX 90004
BOWLING GREEN, KY
42102-9004

55504
Rev. B
08/99

®

ARISTOCRAT™

MODEL V36EC2

LOUVERED CIRCULATING

WOOD-BURNING FIREBOX

21 

3

/

8

42

35

36

41

23 

1

/

4

0 IN. TO
TOP
SPACER

AIR KIT K/O

GAS LINE K/O

3/4" AIR SPACE
BACK AND SIDES

OUTSIDE AIR
(LEFT SIDE ONLY)

0 IN. TO
BOTTOM

1

/

2

8

19 

5

/

8

9

33 

5

/

16

8 IN.
EACH SIDE

HEARTH EXTENSION
52 IN. X 16 IN.

NOT LESS
THAN 18 IN.
TO PERPENDICULAR
SIDEWALL

NO COMBUSTIBLE
MATERIAL ON FACE

COMBUSTIBLE
WALL BOARD

2 IN. AIRSPACE
TO COMBUSTIBLE
MATERIAL

1

/

4

5/8

13

ROUND TOP
TERMINATION

STORM
COLLAR

17.22

16.07

35.75

(2-PIECE BOTTOM

REFRACTORY)

ECONO-TOP
TERMINATION

FLASHING

FIRESTOP

Summary of Contents for ARISTOCRAT V36EC2

Page 1: ...NG GREEN KY 42102 9004 55504 Rev B 08 99 ARISTOCRAT MODEL V36EC2 LOUVERED CIRCULATING WOOD BURNING FIREBOX 21 3 8 42 35 36 41 23 1 4 0 IN TO TOP SPACER AIR KIT K O GAS LINE K O 3 4 AIR SPACE BACK AND...

Page 2: ...ar sidewall A 2 inch minimum air space clearance between combustible materials and the chimney must be absolutely maintained A 16 1 2 inch inside chase dimension is recommended as a minimum size A 3 4...

Page 3: ...rt if properly locked It is not necessary to add screws to keep the chimney together FIRESTOP SPACERS VFS 8DM Firestop spacers are required at each point where the chimney penetrates a floor or ceilin...

Page 4: ...ar opening must be cut STEP 1 Determine the center point through which the pipe will penetrate the roof STEP 2 Determine the pitch of the roof Pitch is the distance the roof drops over a given span us...

Page 5: ...TION TEMPORARILY DO NOT DISCARD REMOVE GAS CONDUIT COVER Figure 14 OUTSIDE OF FIREPLACE GAS LINE CONDUIT REPACK INSULATION INCOMING 1 2 BLACK IRON PIPE PROVIDE ENOUGH THREADED END FOR FITTING CONNECTI...

Page 6: ...handling during installation These should be sealed with non combustiblematerials Ifthefireboxismountedonaraisedplatform insulate below the platform to prevent the entry of cold air through the firebo...

Page 7: ...e sides and the top of the firebox face It is important that combustible materials do not overlap the face itself Brick tile or other noncombustible materials may be applied to the face provided that...

Page 8: ...8DM 0 to 6 12 V12F 8DM 6 12 to 12 12 EMBER PROTECTOR EP 36 ROUND TOP TERMINATION VRTL 8DM VRTTL 8DM VADS 8DM ECONO TOP TERMINATION VETO 8DM VETLO 8DM GLASS DOOR KIT VDG36E Brushed Brass VDP36E Polishe...