background image

1

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT DRAWN TO SCALE.

11

•  The burner orifices provided in this 

kit are only for use at elevations of 

0–4,500 ft (0–1372 m) in the U.S.A. 

and Canada. At higher elevations, 

the BTU input must be derated by 

4% for every 1,000 ft (305 m) to 

maintain the proper ratio of gas to 

air. If the installer must convert the 

unit to adjust for varying altitudes, 

a deration information sticker must 

be completed by the installer and 

attached to the appliance at time of 

conversion. Contact your local gas 

supplier for deration requirements 

for your area.

In Canada:

•  The conversion shall be carried out 

in accordance with the requirements 

of the provincial authorities having 

jurisdiction and in accordance 

with the requirements of the CAN/

CSA-B149.1 Installation code.

Au Canada:

•  La conversion devra être 

effectuée conformément aux 

recommandations des autorités 

provinciales ayant juridiction et 

conformément aux exigences du 

code d'installation CAN/CSA-B149.1.

KIT CONTENTS

•  (2) Brass Burner Orifices

•  (1) Pilot Orifice

•  (1) SIT Regulator Conversion Kit

•  (2) Gas Conversion 

Information Labels

REQUIRED TOOLS

•  5/32 in. Allen Wrench

•  Torx Bit (T20 with 1/4 in. shank) or 

Flat-head Screwdriver

•  1/2 in. Open-End Wrench

Description

Model No.

Cat.

No.

 Natural Gas to 

Propane

GCK-RAPNP

H8540

Table 1: Gas Conversion Kits

GENERAL INFORMATION

Gas conversion kits adapt the appliance 

from the use of one type of gas to 

another. This kit contains all components 

required to complete the conversion, 

as well as a self-adhesive label with gas 

conversion information to apply to the 

appliance rating plate.

•  Before installing gas components, apply 

pipe joint compound or Teflon tape to 

all pipe fittings. Always use propane-

resistant joint compounds. Never use 

pipe joint compounds on flare fittings.

INSTALLATION INSTRUCTIONS FOR GAS CONVERSION KITS FOR USE WITH  

RHAPSODY

®

 LINEAR DIRECT VENT GAS FIREPLACES WITH SIT PROFLAME SYSTEMS

[FIREPLACE MODELS RHAP42N, RHAP54N] 

P/N 506019-90 Rev. B   05/2015

HEARTH PRODUCTS

KITS AND ACCESSORIES

GAS CONVERSION KIT

RHAPSODY

®

 LINEAR / SIT PROFLAME

P506019-90

  

WARNING

RISK OF PERSONAL INJURY, 

DEATH, OR PROPERTY DAMAGE. 

This conversion kit shall be installed 

by a qualified service agency in 

accordance with the manufacturer’s 

instructions and all applicable codes 

and requirements of the authority 

having jurisdiction. If the information 

in these instruction is not followed 

exactly, a fire or explosion or 

production of carbon monoxide may 

result, causing property damage, 

personal injury, or loss of life. The 

qualified service agency is responsible 

for the proper installation of this 

kit. The installation is not proper 

and complete until the operation of 

the converted appliance is checked 

as specified in the manufacturer’s 

instructions supplied with the 

kit.The qualified service agency 

performing this installation assumes 

responsibility for this conversion.

 

AVERTISSEMENT

RISQUE DE BLESSURE, MORT OU 

DOMMAGE À LA PROPRIÉTÉ 

Cette trousse de conversion doit être 

installée par un technicien agréé, 

selon les instructions du fabricant 

et selon toutes les exigences et tous 

les codes pertinents de l’autorité 

compétente. Assurez-vous de bien 

suivre les instructions dans cette 

notice pour réduire au minimum 

le risque d’incendie, d’explosion 

ou la production de monoxyde 

de carbone pouvant causer des 

dommages matériels, des blessures 

ou la mort. Le tecnicien agréé est 

responsable de l’installation de 

cette trousse. L’installation n’est 

pas adéquate ni complète tant que 

le bon fonctionnement de l’appareil 

converti n’a pas été vérifié selon les 

instructions du fabricant fournies avec 

la trousse. Le fournisseur de service 

qualifié ayant réalisé l'installation 

assume les responsabilités liées à la 

conversion.

 

CAUTION

RISK OF PERSONAL INJURY OR PROPERTY DAMAGE. 

•  Never operate fireplace with glass door assemblies removed.

•  Securely tighten door latch screws when reinstalling glass door assemblies to 

prevent doors from falling out.

•  Handle glass door assemblies with extreme care. Replace damaged glass door 

assemblies with approved replacement assemblies only.

•  The door assemblies contain ceramic glass. Handle with care to prevent 

damage. If the door frame or glass becomes  damaged, replace the entire glass 

door assembly with a manufacturer-approved replacement assembly only. Do 

not attempt to substitute any materials used on door assemblies or replace 

cracked or broken glass with any other materials. 

  

WARNING

HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL 

COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.

•  Fireplaces surfaces get EXTREMELY HOT!

•  Install only when fireplace is OFF and COLD.

•  The glass on the front of the fireplace reaches EXTREMELY HIGH temperatures 

and can cause severe burns if touched. Even after the gas is turned off, fireplace 

surfaces remain extremely hot.

•  Keep children away from an operating fireplace. Closely supervise children in 

any room where a fireplace is operating to prevent contact with glass. 

f i r e - p a r t s . c o m

Summary of Contents for RHAPSODY RHAP42N

Page 1: ...followed exactly a fire or explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit The qua...

Page 2: ...wer edge of the glass door frame Then swing the lower edge of the bezel away from the door and lift up to unhook the bezel upper flange from the top edge of the glass door frame see Figure 1 CROSS SECTION Bezel Upper Flange Glass Door Frame Bezel Lower Flange Figure 1 Removing Optional Bezel 4 Remove the optional surround if installed by removing the nine 9 screws securing it see Figure 2 Figure 2...

Page 3: ...Access Panel and Gasket Right Burner Bracket Venturi Remove two screws to remove burner assembly Burner Assembly Burner Orifice Right Burner Bracket Figure 4 Accessing the Control Compartment Gas Valve Assembly Burner Orifice Gas Valve Burner Assembly Rotate burner to release air shutter adjustment rod from air shutter lever Air Shutter Adjustment Rod Figure 5 Air Shutter Adjustment fire parts com...

Page 4: ... of the orifice NOTE The new orifices are attached to the back cover of this manual Fireplace Model Natural Gas drill size inches Propane drill size inches RHAP42N 40 0 098 in Cat No 69L96 54 0 055 in Cat No 99K79 RHAP54N 32 0 116 in Cat No H8002 51 0 067 in Cat No H0922 Standard size installed at factory Available as field conversion only Table 2 Burner Orifice Sizes 0 4500 ft 0 1372 m s i z e Fi...

Page 5: ...liance is first lit the entire flame may be blue and will gradually turn yellow orange during the first 30 minutes of operation After 30 minutes of operation if the flame is blue or if the flame is orange with evidence of sooting black tip the air shutter opening may need to be adjusted If the air shutter opening is closed too far sooting may develop Sooting is indicated by black puffs developing ...

Page 6: ...P42N here RHAP54N ORIFICE AND LABEL Staple orifice and conversion label for RHAP54N here P506019 90 Printed in U S A 2015 Innovative Hearth Products P N 506019 90 Rev B 05 2015 1508 Elm Hill Pike Suite 108 Nashville TN 37210 IHP us com InnovativeHearthProductsreservestherighttomakechanges atanytime withoutnotice indesign materials specifications prices and also to discontinue colors styles and pro...

Reviews: