19
4º- It is important that the bolts or rivets used to secure the air outlets be fixed from
the bottom up so that a minimum height is allowed inside the insert to not interfere
with the proper extraction of the equipment during maintenance, see Figure 18.
5º- Once the grilles are fitted, the ducted air pipes are attached to them. The use of
metal cable clamps is recommended. It is important to ensure that the air pipes are
not in contact with the exhaust pipe or pellet duct to prevent noise or vibration during
operation of the insert.
•
Example of a ducted air installation:
Figure 19
–
Equipment installation
•
In the installation example (Figure 19), it can be verified that the pipes are placed
to channel the hot air outlet to the room where the insert is installed, but could be
installed to carry hot air to neighboring rooms. The maximum length of pipes without
installing an air extraction box is 3-4m.
•
The amount of air flowing to the front of the equipment and that flowsg through the
tubes to channel the hot air can be adjusted using the accessory to open the door and
the safety latches. Put the back part of the accessory between the grate in its central
part as shown in figure 20, you can check that there is a piece that fits perfectly and is
able to rotate and move a deflector that causes the air to be directed towards the Front
or to the air pipes. For safety, there is always a minimum amount of air that has to