Wireless Sensor Device Manager
Exporting the Measurement Collection Period
52
SKF Wireless Machine Condition Sensor
Service Manual
Exporting the Measurement Collection Period
The data collection schedule in the
Sensor
>
Data Collection
tab is automatically
exported to update the corresponding points in Analyst.
When using Command 9 as the Trend Command in Device Manager, for velocity and
enveloped acceleration point, the most frequent data collection interval between the
overall and the waveform is exported to the
Schedule
tab in the
POINT
’s properties in
Analyst. However, when using Command 93, the waveform period is always exported
even if the cyclic update period is more frequent.
Manual Data Collection
Overall Data
If you need to collect overall data manually, follow these steps.
Deselect the
Use Cache
check box
in the gateway’s
Admin
tab to
disable the automatic data
collection function.
To export the manual overall data
to Analyst, you must temporarily
select
Command 9
as the
Trending Command.
Select a sensor in the Device
Manager hierarchy.
Open the
Data Collection
tab.
Select
Command 9
.