The P+F Gateway’s Web Page
Verifying the P+F Gateway’s Firmware Version
16
SKF Wireless Machine Condition Sensor
Service Manual
Known Issue
Solution
You see the message, “Microsoft Internet
Explorer is not able to show the P&F
gateway web page.”
Cause: The computer is missing Java to
run Java Applet.
Download and install Java from this link
http://java.com/en/download/index.jsp
Verifying the P+F Gateway’s Firmware Version
If the network P+F gateway was
not
purchased from SKF, verify that the software
Revision is 2.5 or later and the software version is 02.00.02 or later.
Figure 8
.
Verify the Gateway’s Firmware Version.
Known Issues with the Firmware
The following are known issues with the P+F gateway’s firmware, current software
release 2.5 version 2.00.02:
Known Issue
Solution
The web pages do not refresh
automatically.
Manually refresh the web pages to get updates.
The manual refresh is very slow if the
network has many sensors (more than
50) trying to join the network.
No solution. Wait until the refresh is complete.
P1 or P2 profile options are offered, but
P2 profile (slower) does not work.
No solution at this time – P2 does not work in
the P+F gateway’s firmware in the current
version.