The Basics
Issuing Commands to the Sensor
SKF Wireless Machine Condition Sensor
5
Service Manual
Issuing Commands to the Sensor
Figure 2
.
Wireless Sensor LED and Push Button.
You activate and issue manual commands to the wireless sensor by pressing and
holding its push button for various durations - as you count a number of LED blinks.
Releasing the push button after a specific number of blinks will issue a specific
command to the sensor.
Activate the Sensor
Firmly press and then quickly release the sensor’s push button. The sensor’s green LED
immediately blinks once, pauses, then blinks in an accelerating manner, pauses, and
then blinks a short burst to indicate the sensor is active.
Deactivate the Sensor
Firmly press the sensor’s push button and count four blinks, then release. The sensor’s
green LED blinks in a decelerating manner, and then stops. The sensor is deactivated.
(Counting five or six blinks will also deactivate the sensor.)
LED
Push button