9) In the following example, the target waveform is acquired from bar 1, so the
Set Ref
button is pressed.
Figure 138.
Reference wave EAR.
10) A dialog box will appear with a warning that you that the voltage will lock at and start
at the target voltage level for all subsequent test, overriding the zero-volt interlock
feature.
Figure 139.
Zero start override warning message.
11) Move the test fixture to the second bar (2–3).
12) Press the test button or footswitch. The analyzer will energize Lead 1 at the preset
voltage and the waveform will be displayed on the screen as the red wave. The
reference is also displayed as the blue waveform. A reference-to-bar EAR value will
be displayed in the
Ref Bar EAR
field.
13) If the EAR percentage is greater than the tolerance, the field background will turn
red indicating a failed test. If the EAR percentage is under or equal to the tolerance,
the background of the
Ref-Bar EAR
box will be white, indicating a passing test.
140
PUB CM/I4 71-015 EN V13.2 Static Motor Analyzer—Baker AWA-IV User Manual
Using the Baker ZTX with Baker AWA-IV analyzers