5) The Surge test parameters will need to be adjusted for both Test IDs. Given that you
are now aware of the low resistance of the armature, take steps to code the surge
test sequence specifically for the low resistance. This equates to a lower value of
time-base, (not necessarily 10, it could be 50).
6) For the shunt fields Test ID, employ the hard coded time-base, and the Hi L
technique. The following illustrations show the steps to program the time-base,
specifically for the shunt fields.
7) Set micro-seconds to 200, and be sure to select Hi L.
8) Click
Close
then click
Save
to commit the changes for the Test ID. Uncheck the
Edit
Test ID
box.
Figure 116.
Surge test settings for shunt fields Test ID; Hi-L selected.
114
PUB CM/I4 71-015 EN V13.2 Static Motor Analyzer—Baker AWA-IV User Manual
Special features of the Baker AWA-IV
Summary of Contents for Baker AWA-IV 12 HO
Page 1: ...SKF Static Motor Analyzer Baker AWA IV User manual...
Page 2: ......
Page 22: ...2 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual About this manual...
Page 126: ...106 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual Test procedures...
Page 206: ...186 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual...
Page 213: ......