Conducting Surge tests with the Baker PP30 three-phase test lead power
pack
1) After setting up the power pack and analyzer, on the Baker AWA-IV, select the motor
to be tested from the
Explore
tab.
2) Click on the
Tests
tab to get to the main testing screen.
3) Select a Test ID that uses a voltage requiring the power pack, or create a test that
does.
4) Click on the test configuration button at the end of the Surge test row. The
Surge
Test
setup window will appear.
5) Adjust the voltage required so that surge voltage is at least 5000 volts.
6) Enable the power pack by checking the
Enable PP
box. An error message will
appear if a voltage below the minimum for the power pack is programmed after the
Enable PP
box is checked.
7) Click on the
Pause between Leads
button in the
Surge Test
setup window.
Figure 128.
Setting up Surge test for power pack.
8) Turn the power packs’s
Voltage
Output Control
know on the power pack to
MIN
(full
counterclockwise).
9) Select the
Surge
test using the
Function
knob on the power pack.