Most concern is typically given to the current at the end of the voltage step. End-of-step
currents should be linear. If they are not, an insulation problem is often indicated. The data
in the table below the graph shows the test time per step, the voltage of each step, the
measured end-point current, and the MegOhm value at each end point.
Figure 55.
Step/Ramp Voltage view showing current vs. time.
In the graphic displays, you can hold down the left mouse button and drag a box around an
area of the screen to zoom in on the area. You can also use your finger to draw the box
around the area you want to zoom in on.
Press the space bar on the keyboard to zoom back out to full view.
54
PUB CM/I4 71-015 EN V13.2 Static Motor Analyzer—Baker AWA-IV User Manual
Baker AWA-IV software overview