15) As the test results are transferred, any TestID that is used will be remembered for
the end step. At that end step, all such referenced TestIDs (for any transferred test
results) will be transferred across.
16) The software adds test records that do not exist in the destination database. It
compares the time/date stamps with existing test result records; if the source time/
date equals a test result record in the destination database, it does not transfer the
record. If the software does not find a matching time/date, it adds the source test
result record to the destination database.
17) The software creates a log during the data transfer process. Information logged
includes source/destination database names, Motors IDs added, the number of
records updated, and Test ID data updates (if update Test IDs box is checked). If the
transfer encounters problems, it logs the Motors ID and reason the transfer failed.
You can print this log by clicking on the
Print Log
button.
Transferring Test IDs
Test IDs can be transferred separately from Motor IDs.
To transfer Test IDs, you will follow essentially the same process described in the
“Transferring motor and test result data” section above. The source and destination
databases must be open before a transfer can be performed. When both databases are
open, the
Transfer Test IDs
button will be enabled. Click on this button to open the
Transfer
Test ID’s
window.
Figure 14.
Transfer test IDs.
The window displays all Test IDs in the source database, along with the Test IDs currently
found in the destination database. Choose the source Test IDs to transfer by highlighting
them. To select multiple IDs, use the Shift and Ctrl keys on your keyboard while clicking on
the Test IDs.
With the desired Test IDs highlighted, click on the
Transfer
button to start the transfer.
The software will transfer (copy) the requested Test IDs to the destination database. If a Test
ID exists in the destination database, it will overwritten with the parameters assigned to the
selected TestID.
18
PUB CM/I4 71-015 EN V13.2 Static Motor Analyzer—Baker AWA-IV User Manual
Database management and maintenance
Summary of Contents for Baker AWA-IV 12 HO
Page 1: ...SKF Static Motor Analyzer Baker AWA IV User manual...
Page 2: ......
Page 22: ...2 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual About this manual...
Page 126: ...106 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual Test procedures...
Page 206: ...186 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual...
Page 213: ......