Step Voltage test results table—(TestResultsPrgHiPot)
The TestResultsPrgHiPot table contains a record for a test result, only if a Step Voltage Test
test has been performed. Then a record containing the motor_key and same test_resultno
for each step of the test is added to the table.
Table 31.
Step voltage table field descriptions.
Field name
Type
Description
test_resultno
Long integer
Foreign key used to link test result records.
motor_key
Long integer
Motor Identification key.
step_order
Long integer
Enumerator used to sort results in step
order.
step_voltage
Long integer
Voltage for the given test interval.
step_time
Short integer
Length of step in seconds.
step_ramp_rate
Short integer
Not used at this time.
step_min_Meg-Ohm
Long integer
Minimum Meg-Ohms aloud for the step.
Meg-Ohm_at_endstep
Long integer
Meg-Ohm value at the end of the step.
current_at_endstep
Double
Current in micro amps at the end of the
step.
voltage_1sec
Memo
Comma delimited field containing the
voltage for each second of the interval,
including ramping voltage.
current_1sec
Memo
Comma delimited field containing the
current for each second of the interval,
including current during ramping of voltage.
time_1sec
Memo
Comma delimited field containing the times
progression for each second of the interval,
including time during ramping of voltage.
PUB CM/I4 71-015 EN V13.2 Static Motor Analyzer—Baker AWA-IV User Manual
169
Database definition
Summary of Contents for Baker AWA-IV 12 HO
Page 1: ...SKF Static Motor Analyzer Baker AWA IV User manual...
Page 2: ......
Page 22: ...2 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual About this manual...
Page 126: ...106 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual Test procedures...
Page 206: ...186 PUB CM I4 71 015 EN V13 2 Static Motor Analyzer Baker AWA IV User Manual...
Page 213: ......