Operating manual - English
UNOCODE 299
Copyright Silca 2002
43
7
MAINTENANCE
ATTENTION: for repairs or replacement of parts for maintenance, the ‘CE’ mark is guaranteed only if original spare
parts provided by the manufacturer are used.
Although the UNOCODE 299 key-cutting machine does not require special maintenance, it is advisable to
check and, if necessary, replace the parts subject to wear and electric/electronic parts (fuses, circuit
boards, etc.) in the event of faulty operation.
ATTENTION: for normal servicing of the burnished mechanical parts, we recommend using lubricants or
protective oil, e.g. WD40 or similar. Do not apply to the parts used for electrical contact (clamps,
decoders, cutters, gauging templates, etc.). Do not contaminate the electronic parts with the oil.
Replacement is simple and can be carried out by the operator consulting the instructions.
Before starting any type of maintenance (controls or replacements), read the instructions below:
•
never carry out maintenance with the machine switched on
•
always remove the main power supply cable
•
strictly follow all the instructions in the manual
•
use original spare parts (see Spare Parts sheet provided).
7.1
T
ROUBLE SHOOTING
FAULT
PROBABLE CAUSE
Machine is on, with no
message on its display.
check to see if the back fan is working
not working:
a) emergency button activated
b) general fuses in the power socket are faulty
working:
a) fuse F3 on electronic control board is faulty
b) connection wire between display and electronic circuit board loose
c) defective display
cutter
motor
not
working.
a) the closed protective shield is not making proper contact with the safety microswitch (fig.
33).
b) the F1 fuse on the electronic control board is faulty
c) motor wire not properly attached to the connector
d) defective electronic control board
e) motor cut-off
WARNING: this may derive from inappropriate or heavy use of the key-cutting machine or a
fault with the motor itself. DO NOT USE THE MACHINE and call Technical Silca Dept. to
determing the cause of activation of the cut-off.
X, Y and B axes motors
are not working.
None
of
the
motors
work-
ing:
a) fuse F2 on the electronic control board faulty
b) the wiring between the transformer and electronic control board is
loose or the connector is not seeded properly.
c) defective electronic control board
Only
one
motor
is
not
working:
a) the connection wires between the motor and the electronic control
board are loose or the connector is not seeded properly
b) defective electronic control board
Protective
shield
is
closed but the display
reads “‘close shield”.
a) the closed protective shield is not making proper contact with the microswitch (D3) (fig.
33)
b) the F4 fuse on the electronic control board is faulty
Keyboard not working
(partially or completely)
a) the keyboard connector is not properly connected to the interface board (fig. 32)
b) the wiring between the keyboard/display unit and electronic control board is not properly
attached to the relative connectors
c) defective keyboard
d) defective electronic control board
Summary of Contents for Unocode 299
Page 1: ...D425337XA vers 6 0 Operating manual...
Page 62: ......
Page 64: ...Operating manual English UNOCODE 299 Copyright Silca 2002 Appendix IV...
Page 65: ...Operating manual English UNOCODE 299 Copyright Silca 2002 Appendix V...
Page 66: ...Operating manual English UNOCODE 299 VI Appendix Copyright Silca 2002...