8.22
Object 3002h: Termination Resistor
This object is used to activate the termination resistor in case the IK360 is used at the edges of
the transmission line ( to avoid reflection of data back into the line) and / or high transmission
rates (>50 kB).
Subindex
Description
Data Type
Default Value
Access
Restore after
BootUp
0
Activate
Termination
Resistor
Unsigned 8
0
rw
yes
For Activation*
– Write 1 decimal to the sub index 0 of the object.
For De-activation
– Write 0 decimal to the sub index 0 of the object.
*If activated, the termination resistor is only enabled while the device is powered.
8.23
Object 3022h: Digital Recursive Filter
This particular object controls the weighting factor of the recursive filter. If set to 0, the filter is
deactivated. Valid values range from 0 to 1000. The value specifies the weighting factor for the
slope values obtained earlier, divided by 1000. Therefore, mathematically the weighting factor
ranges from 0 to 1.
Subindex
Description
Data Type
Default Value
Access
Restore after
BootUp
0
Digital
Recursive
Filter
Unsigned 16
0
rw
yes
8.24
Object 3100h: Moving Average Filter
This object contains the number of values, which are averaged.
Subindex
Description
Data Type
Default Value
Access
Restore after
BootUp
0
Moving
Average Filter
Unsigned 16
100
rw
yes
Range of values accepted: 0d to 250d.
8.25
Object 6000h: Resolution
This object sets the resolution per 1°.
Subindex
Description
Data Type
Default Value
Access
Restore after
BootUp
0
Resolution
Unsigned 16
-
rw
no