IK360 -CAN
x
Date: 23.01.2017 Page 12 of 41 Art.no. 86089 Mod. Status 10/17
IK360 (2 axis)
5
IK360 Software Configuration
This chapter succeeds the hardware configuration (i. e. installation) as in real time. IK360 is a
very flexible device and hence all the parameters can be programmed via CAN bus itself even
when attached. This enables remote configuration. This chapter is primarily divided into two
parts. In first part the methodology is described for putting the IK360 into operation and in the
second part the PDO/SDO programming of IK360.
5.1
Important factory settings
Description
Object
Value
Device Type
1000h
0 x 3019A (IK360 1 axis)
0 x 4019A (IK360 2 axis)
Cyclic Timer
2200h
00h (0 ms)
Resolution
6000h
0Ah (0.01°)
Node Number
3000h
00h (NN = 1)
Baud Rate
3001h
03h
(125 kB)
PDOs
6010h
Note: The factory settings should be noted carefully upon installation. Few of the
parameters have to be re-programmed in order to make the IK360 inclinometers
compatible with the controller or the already existing CAN bus to which it is going to be
installed on.