The inclinometer is connected via a 5 pin round M12 connector (Standard M12, male connector
on IK360, female connector at connection cable).
Pin
Description
1
CAN Ground
2
10-30 V supply voltage
3
0 V supply voltage
4
CAN High
5
CAN Low
4.2
Installation precautions
ATTENTION !!!
Do not remove or mount while the inclinometer is under power!
Avert any modifications to the plastic molding!
Avoid mechanical load!
4.3
Mounting instructions
IK360 is a pre-calibrated device, which can be put into immediate operation, upon simple and
easy installation with a three point mount and setting of preset. Its compact design and
installation "anywhere" makes it versatile.
The IK360 inclinometer can be mounted in any number of fashions, depending on the situation.
The mounting surface must be plane and free of dust and grease. It is absolutely necessary,
that the IK360 inclinometer is connected to potential equalization in a workmanlike manner. For
mounting we recommend cheese head screws with metrical thread M4 or UNC bolts #6 for the
best possible and secure mounting. Use all the 3 screws for mounting, but restrict the tightening
torque in the range of 1.5
– 2.5 Nm for the screws. The M12 connectors are to be perfectly
aligned and screwed till the end with a tightening torque in the range of 0.4 -0.6 Nm. Use all the
three screws for mounting and also note to use the same tightening torque for all the screws. An
appropriate and well secured counter connector is also an important constraint for attaining the
stated IP69K protection.
Prior to installation, please check for all connection and mounting instructions to be complied
with. Please also observe the general rules and regulations on low voltage technical devices, for
safety and sustainability of IK360 Inclinometers over long period of time.