![Siemens VDO DTCO 1381 Technical Description Download Page 85](http://html.mh-extra.com/html/siemens/vdo-dtco-1381/vdo-dtco-1381_technical-description_382822085.webp)
Service only
Data handling
4.2 The flow of data and memory behaviour
Edition 07/2007
Technical Description DTCO 1381
4 - 11
TD00.1381.00 13
2 102
Faults (errors)
The DTCO 1381 saves faults (errors) with a resolution of one second.
The following data will be saved for every fault (error):
Calibration data
The DTCO 1381 registers and saves the following calibration data in
its data memory:
•
Programmed calibration parameters at the time point of the acti-
vation
•
The first calibration after activation
•
The first calibration in the current vehicle (depending on the
chassis number)
•
The 5 most recent calibrations
•
Date and purpose of the calibration
– Activation (1)
– Initial installation (2)
– Installation (3)
– Regularly inspection (4)
•
Name and address of the workshop
•
Number of the workshop card, issuing member state, validity
Fault
Saving regulations
Recorded data
Card faults
• The 10 most recent driver card faults
• Begin – date and time
• End – date and time
• A card’s type, number, and issuing
member state.
Recording equipment fault • The 10 most recent faults of each fault
type
• The first fault after the most recent cali-
bration
• Type of fault
• Begin – date and time
• End – date and time
• The type, number, and issuing member
state of an inserted card at the
beginning and/or end of the fault.
If several calibrations are performed on one calendar day, only the
last calibration will be saved.
Summary of Contents for VDO DTCO 1381
Page 4: ...S e r v i c e o n l y IV Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 33: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 2 Technical data ...
Page 53: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 3 Operating the DTCO 1381 ...
Page 74: ...S e r v i c e o n l y 3 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 75: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 4 Data handling ...
Page 105: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 5 Installation ...
Page 152: ...S e r v i c e o n l y 6 16 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 153: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 7 Preprogramming ...
Page 167: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 9 Activation ...
Page 179: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 10 First calibration ...
Page 200: ...S e r v i c e o n l y 10 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 201: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 11 Regularly inspection ...
Page 222: ...S e r v i c e o n l y 11 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 233: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 13 Events and faults ...
Page 270: ...S e r v i c e o n l y 13 38 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 271: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 14 Appendix ...
Page 302: ...S e r v i c e o n l y 14 32 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...