The DTCO 1381 registers in the internal data memory the activities
and data of all drivers and the vehicle itself over a time period of
at least 365 calendar days in accordance with CR (EEC) 3821/85,
annex I B.
The following data will be registered:
•
Device identification data of the DTCO 1381
•
Identification data of the attached KITAS 2171
•
Security data (cryptographical key)
•
Insertion and withdrawal of the driver cards, for 2190 drivers
•
Driver activities
•
Location at the beginning and end of the working time
•
Distance
•
Detailed speed (the last 24 hours of driving time)
•
Events
•
Faults
•
Calibrations
•
Control activities
•
Lock-in / lock-out from the company
•
Download activities
•
Specific conditions
•
Movement data of the vehicle
The saved data can be shown on the display of the DTCO 1381,
printed on the integrated printer, or transferred (copied) over the
interfaces to external devices.
In general, the following applies:
• If the memory capacity is exhausted, the oldest data will be con-
tinuously overwritten.
• Data elements with unknown or inapplicable content are filled
with FF bytes.
For detailed information on data formats, elements and structures,
please see EU Directive No. 1360/2002, annex 1 "Data glossary".
Summary of Contents for VDO DTCO 1381
Page 4: ...S e r v i c e o n l y IV Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 33: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 2 Technical data ...
Page 53: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 3 Operating the DTCO 1381 ...
Page 74: ...S e r v i c e o n l y 3 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 75: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 4 Data handling ...
Page 105: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 5 Installation ...
Page 152: ...S e r v i c e o n l y 6 16 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 153: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 7 Preprogramming ...
Page 167: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 9 Activation ...
Page 179: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 10 First calibration ...
Page 200: ...S e r v i c e o n l y 10 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 201: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 11 Regularly inspection ...
Page 222: ...S e r v i c e o n l y 11 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 233: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 13 Events and faults ...
Page 270: ...S e r v i c e o n l y 13 38 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 271: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 14 Appendix ...
Page 302: ...S e r v i c e o n l y 14 32 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...