![Siemens VDO DTCO 1381 Technical Description Download Page 255](http://html.mh-extra.com/html/siemens/vdo-dtco-1381/vdo-dtco-1381_technical-description_382822255.webp)
Service only
Events and faults
13.4 Messages and troubleshooting measures
Edition 07/2007
Technical Description DTCO 1381
13 - 23
TD00.1381.00 13
2 102
Yr
%
JOUFSOBMáGBVMU
8000001177 Fault or interruption in the communication with an external
display instrument (reset monitoring).
Measures
– Check the function / configuration of the DTCO 1381,
correct if necessary.
– Check the connection cable between the DTCO 1381 and
the display instrument:
a) Pin assignment
b) Connection
c) Specifications
– Check functionality of the display unit, e.g. send reset-
message
– Check functionality of the DTCO 1381.
– Check calibration data of the DTCO 1381 (variant / con-
figuration).
Replace any defective components if necessary.
Comment
Monitoring of this fault depends on the configuration of the
DTCO 1381:
• Monitoring of this fault can be activated or deactivated
(CANEVCfg).
• The fault can be suppressed for a certain period after
ignition "on" (ErrorManagementInitialisationInhibit).
The DTCO 1381 may not be the cause of the error.
1)
Yr
Yr
$
JOUFSOBMáGBVMU
4000000400
4000000500
Fault in the card mechanics.
Possible causes
• Card lock not closed
• General error in the card mechanics
Measures
– Re-insert tachograph card.
– Request the tachograph card again.
– Interrupt continuous voltage (perform restart).
If the error message continues to appear despite these
measures, replace the DTCO 1381.
Comment
Any inserted tachograph card is ejected. This error is reset
when a tachograph card has been inserted correctly.
1)
2)
DTCO 1381 display
Picto. AP
Error text
MC Error code
Meaning, cause and measures
1)
These warning messages will be displayed repetitively every hour until the cause is withdrawn.
2)
These warning messages are not saved in the date memory during calibration mode.
Summary of Contents for VDO DTCO 1381
Page 4: ...S e r v i c e o n l y IV Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 33: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 2 Technical data ...
Page 53: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 3 Operating the DTCO 1381 ...
Page 74: ...S e r v i c e o n l y 3 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 75: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 4 Data handling ...
Page 105: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 5 Installation ...
Page 152: ...S e r v i c e o n l y 6 16 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 153: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 7 Preprogramming ...
Page 167: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 9 Activation ...
Page 179: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 10 First calibration ...
Page 200: ...S e r v i c e o n l y 10 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 201: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 11 Regularly inspection ...
Page 222: ...S e r v i c e o n l y 11 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 233: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 13 Events and faults ...
Page 270: ...S e r v i c e o n l y 13 38 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 271: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 14 Appendix ...
Page 302: ...S e r v i c e o n l y 14 32 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...