Technical data
2.1 DTCO 1381
Edition 07/2007
Technical Description DTCO 1381
2 - 11
TD00.1381.00 13
2 102
2.1.5 Technical data
* Option
Measurement range
0 ... 220 km/h
LCD
2 lines with 16 characters each, illuminated, dimmable*
Installation angle of display
± 30°
Character height
6.3 mm
Operating voltage
24 V DC or 12 V DC*
Power consumption
12 V DC*
24 V DC
Standby typical
Operation max.
30 mA
5 A
20 mA
3 A
External fuse protection (typical)
5 A
5 A
Operating temperature
-25 °C ... +70 °C
Storage temperature
-40 °C ... +85 °C
Pulse range v
4000 to 25000 pulses/km
Maximum frequency v
1,5 kHz
Pulse range n
2000 to 64000 pulses/1000 revolutions
Maximum frequency n
5 kHz
Inputs
KITAS 2171, n-sensor*, additional inputs*
Outputs
2 x v-pulses, 1 x 4 pulses/m, TCO warning output (FM LED)
Interfaces
Calibration interface, download interface, CAN interface, Info interface
Accuracy (under test conditions)
➥
See chapter 8.2 "Permissible error limits", page 8-5.
EMC
RL 2006/28/EC
Vibrations
ISO 16750-3 sec. 4.1.3.2.4.2, test VIII code VA
Sinusoidal oscillations according to IEC 60068-2-6 test Fc:
2-11 Hz,
±
10 mm; 11 - 300 Hz, 5g, 3 x 15 h
Oscillations random according to IEC 60068-2-64 test Fh:
5 - 150 Hz, 0,02 g²/Hz, 3 x 16 h
Material of the connection pins
Surface OL Cu Ag 6
Buffer battery
Lithium cell 3,6 V 1/2 AA (type SB-AA02P)
Housing
Galvanized steel plate
Weight
~ 1300 g
Permissible installation position
± 45° off of horizontal
Possible special equipment
rpm registration, additional stylus, K-Line diagnosis interface,
customer-specific cover, customer-specific display and keypad illumi-
nation, customer-specific output circuit, customer-specific interfaces,
v-pulse output (D6), without CAN
Summary of Contents for VDO DTCO 1381
Page 4: ...S e r v i c e o n l y IV Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 33: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 2 Technical data ...
Page 53: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 3 Operating the DTCO 1381 ...
Page 74: ...S e r v i c e o n l y 3 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 75: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 4 Data handling ...
Page 105: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 5 Installation ...
Page 152: ...S e r v i c e o n l y 6 16 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 153: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 7 Preprogramming ...
Page 167: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 9 Activation ...
Page 179: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 10 First calibration ...
Page 200: ...S e r v i c e o n l y 10 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 201: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 11 Regularly inspection ...
Page 222: ...S e r v i c e o n l y 11 22 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 233: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 13 Events and faults ...
Page 270: ...S e r v i c e o n l y 13 38 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...
Page 271: ...S e r v i c e o n l y Edition 07 2007 TD00 1381 00 132 102 Chapter 14 Appendix ...
Page 302: ...S e r v i c e o n l y 14 32 Siemens VDO Automotive AG Edition 07 2007 TD00 1381 00 132 102 ...