WL Circuit Breaker Accessory Ratings
1) 250 V DC rating available since October 2005.
Interlock Shunt Trip (100% continuous duty)
Operating range
85 - 110%
Extended tolerance for battery operation at
24V DC, 48V DC, 125V DC, 250V DC
70 - 126%
Rated voltage
AC 50/60Hz
V
110, 230
DC
V
24, 30, 48, 60,
110, 220
Power consumption
AC / DC
VA / W
15 / 15
Minimum shunt trip actuation signal at rated
voltage
ms
60
Opening time of the circuit breaker at rated
voltage
ms
80
Short circuit protection Smallest permissible
fuse
1A
Auxiliary Contacts and Mechanism Operated Contacts (MOC)
Contact rating
Alternating current
50/60 Hz
Rated operational voltage
240 V
Rated operational current, continuous
10A
Rated operational current, making
30A
Rated operational current, breaking
3A
Direct current
Rated operational voltage
24 V, 125 V, 250 V
Rated operational current, continuous
5A
Rated operational current, making
1.1A at 24 V, 1.1A at 125 V, 0.55 A at 250 V
Rated operational current, breaking
1.1A at 24 V, 1.1 A at 125 V, 0.55 A at 250 V
Bell Alarm Switch and "Ready-to-close" Signal Contact
Contact rating
Alternating current
50/60 Hz
Rated operational voltage
240 V
Rated operational current, continuous
5A
Rated operational current, making
8A
Rated operational current, breaking
5A
Direct current
Rated operational voltage
24 V, 48 V, 125 V
250 V DC
1)
Rated operational current, continuous
0.4 A
0.2 A
Rated operational current, making
0.4 A
0.2 A
Rated operational current, breaking
0.4 A
0.2 A
Shunt release, UVR and tripped signaling contacts
Contact rating
Alternating current
50/60 Hz
Rated operational voltage
127 V, 240 V
Rated operational current, continuous
3 A
Rated operational current, making
5 A
Rated operational current, breaking
3 A
Direct current
Rated operational voltage
24 V, 48 V, 125 V, 48 V DC
125 V DC (IEC
rating only)
Rated operational current, making
1.0 A
0.4 A
Rated operational current, breaking
1.0 A
0.4 A
Summary of Contents for UL 489
Page 36: ...5 21 Frame size II 3000 A Frame size III 1 Holes 14 mm 0720 1 0721_nu ...
Page 63: ...7 2 Horizontal connectors 0733_nu top view ...
Page 64: ...7 3 Rear vertical connectors 0734_nu top view rear view ...
Page 65: ...7 4 Front connectors 0736_nu front view top view ...
Page 66: ...7 5 Front connectors and pressure wire terminals 0737_nu top view front view ...
Page 67: ...7 6 7 2 Frame size II fixed mounted version 0494 3_nu ...
Page 68: ...7 7 Class C always 0494 5_nu top view rear view ...
Page 69: ...7 8 2500 0738_nu LH side view front view ...
Page 71: ...7 10 7 4 Frame size III fixed mounted version 0495 1_nu LH side view ...
Page 72: ...7 11 0495 2_nu top view top view ...
Page 73: ...7 12 0495 3_nu top view rear view ...
Page 75: ...7 14 7 5 Door cut outs fixed mounted circuit breaker Frame size I 0735_nu ...
Page 76: ...7 15 Frame size II III 0496_nu ...
Page 77: ...7 16 7 6 Frame size I draw out version 0745_nu ...
Page 78: ...7 17 0746_nu rear view top view ...
Page 79: ...7 18 0747_nu bottom view ...
Page 80: ...7 19 0748_nu ...
Page 81: ...7 20 0749_nu ...
Page 82: ...7 21 7 7 Frame size II draw out version 0490 1_ul ...
Page 86: ...7 25 7 8 Frame size III draw out version ...
Page 87: ...7 26 ...
Page 88: ...7 27 ...
Page 89: ...7 28 7 9 Door cut outs for draw out circuit breakers Frame size I 0750_nu ...
Page 91: ...7 30 7 11 External sensor for neutral conductor WLNCT2 ...
Page 92: ...7 31 WLNCT3 ...
Page 107: ...9 5 I tripping Ground fault tripping ...
Page 351: ......