HMI menu ID Parameter
Description
Default value
[unit]
Value range
Access
level
2.5.6.6.7
Partially Open Current
Level
Define current level to partly
close the analog valve.
10
[mA]
0 to 20
User
2.5.6.6.8
Fully Open Current Lev‐
el
Define current level to fully open
the analog valve.
20
[mA]
0 to 20
User
2.5.6.6.9
Fully Open
Define the dosing amount value
at which the valve will transition
from partial flow to full flow.
0.0
[%]
0.0 to100.0
User
2.5.6.6.10
Partially Closed
Define the dosing amount value
at which the valve will transition
from full flow to partial flow.
0.0
[%]
0.0 to100.0
User
2.5.6.6.9
Fully Open
Define the dosing amount value
at which the valve will transition
from partial flow to full flow.
0.0
[kg]
User
2.5.6.6.10
Partially Closed
Define the dosing amount value
at which the valve will transition
from full flow to partial flow.
1.0
[kg]
User
2.5.6.6.9
Fully Open
Define the dosing amount value
at which the valve will transition
from partial flow to full flow.
0.0
L
User
2.5.6.6.10
Partially Closed
Define the dosing amount value
at which the valve will transition
from full flow to partial flow.
1.0
L
User
2.5.6.6.9
Fully Open
Define the dosing amount value
at which the valve will transition
from partial flow to full flow.
0.0
SI
User
2.5.6.6.10
Partially Closed
Define the dosing amount value
at which the valve will transition
from full flow to partial flow.
1.0
SI
User
2.5.6.7
Fault Handling
2.5.7.1
Name
Define the name of the recipe.
Switching between recipes is
done in dosing operating view.
User
2.5.7.2
Unit
Select unit for the recipe. Unit is
not applied at communication in‐
terface.
Mass flow
kg
● g
● kg
● t
● STon
● T
● oz
● lb
● Custom
User
Default settings
E.6 Dosing
FC430 (From firmware 4.0)
Operating Instructions, 06/2017, A5E39789392-AA
439