![Siemens SITRANS FC430 Operating Instructions Manual Download Page 239](http://html.mh-extra.com/html/siemens/sitrans-fc430/sitrans-fc430_operating-instructions-manual_374486239.webp)
Description
Specification
Process media absolute pressure (min to max) [bar (psi)]
Stainless steel: 1 to 101 (14.5 to 1465)
Hastelloy: 1 to 161 (14.5 to 2335)
Process media viscosity
Gases and non-compressible liquids
Pressure drop
See "Pressure drop curves"
Pressure temperature ratings
See "Pressure - temperature ratings"
11.8
Process variables
Table 11-27 Process variables
Description
Specification
Primary process varia‐
bles
● Massflow
● Density
● Fluid temperature
Derived process varia‐
bles
● Volumeflow
● Corrected volumeflow
● Fraction A:B
● Fraction % A:B
11.9
Bus communication
Table 11-28 HART, MODBUS and Profibus communication
Description
Specification
More information
Manufacturer ID
42 (2A Hex)
Manufacturer ID parameter
Device ID
34 (22 Hex)
Device type parameter
HART protocol revision
7.5
HART protocol revision parameter
Profibus profile
4.0
Profibus protocol revision parameter
Modbus RS485 RTU
-
-
Number of device variables
11
Number of process values, both measured
and derived
Physical layers supported
FSK
Frequency Shift Keyed
Loop-powered
No
4-wire device
Technical data
11.9 Bus communication
FC430 (From firmware 4.0)
Operating Instructions, 06/2017, A5E39789392-AA
239