HMI menu ID Parameter
Description
Default value
[unit]
Value range
Access
level
2.4.3.9.3
Forced value (CH2)
Enter the value for the output
signal when forcing is activated.
Frequency / Pulse
1 Hz
0 to 12500 Hz
User
2.4.3.9.3
Forced value (CH2)
Enter the value for the output
signal when forcing is activated.
Status
Off
● On
● Off
User
2.4.3.9.4
Forced value (CH3)
Enter the value for the output
signal when forcing is activated.
Current
4.00 mA
3.5 to 25 mA
User
2.4.3.9.4
Forced value (CH3)
Enter the value for the output
signal when forcing is activated.
Frequency / Pulse
1 Hz
0 to 12500 Hz
User
2.4.3.9.4
Forced value (CH3)
Enter the value for the output
signal when forcing is activated.
Status
Off
● On
● Off
User
2.4.3.9.5
Forced value (CH4)
Enter the value for the output
signal when forcing is activated.
Current
4.00 mA
3.5 to 25 mA
User
2.4.3.9.5
Forced value (CH4)
Enter the value for the output
signal when forcing is activated.
Frequency / Pulse
1 Hz
0 to 12500 Hz
User
2.4.3.9.5
Forced value (CH4)
Enter the value for the output
signal when forcing is activated.
Status
Off
● On
● Off
User
2.4.3.9.6
Delay time
Select debounce time used to fil‐
ter the hardware input signal.
0.0 ms
● 0.0 ms
● 0.5 ms
● 1.0 ms
● 1.5 ms
● 2.0 ms
● 2.5 ms
● 3.0 ms
● 3.5 ms
● 4.0 ms
● 4.5 ms
● 5.0 ms
● 5.5 ms
● 6.0 ms
● 7.0 ms
● 7.5 ms
User
2.4.3.9.7
Polarity
Set the level of an active input:
active high or active low.
Active high level
● Active high
level
● Active low
level
Default settings
E.5 Inputs and outputs
FC430 (From firmware 4.0)
Operating Instructions, 06/2017, A5E39789392-AA
385