Mounting / connection
4.2 Connection
M200D PROFIBUS/PROFINET
Manual, 08/2014, A5E01577426A/RS-AA/004
117
Auxiliary voltage connection (7/8")
Pin (infeed)
Socket (routing)
Pin
Assignment
1
Switched 0 V (24 V-S DC (-))
2
Unswitched 0 V (24 V-NS DC (-))
3
—
4
Unsw 24 V (24 V-NS DC (+))
5
Sw 24 V (DC 24V-S (+))
Connecting M12 and 7/8" cable connectors
Note
The current of the 7/8" connectors must not exceed 7 A!
1.
Plug the M12 and 7/8" cable connectors into the corresponding circular socket
connectors on the M200D PROFINET communication module. Ensure that the locking
mechanism between the connector and socket is properly applied.
2.
Secure the connectors by tightening the knurled ring nut.
NOTICE
It is not permissible to remove the 7/8" cable connectors while M200D PROFINET is in
operation! Always switch off the 24 V-NS DC electronic/encoder supply and the 24 V-S DC
load voltage supply before you remove or insert the 7/8" cable connector.
Note
Removal of the 7/8" cable connector interrupts the supply to downstream modules.
Note
Closing unused sockets
Always seal all unused sockets using M12 and 7/8" caps in order to achieve degree of
protection IP65.
Summary of Contents for SIRIUS M200D
Page 2: ......
Page 90: ...Functions 3 22 Logbook M200D PROFIBUS PROFINET 90 Manual 08 2014 A5E01577426A RS AA 004 ...
Page 222: ...Appendix A 2 Order numbers M200D PROFIBUS PROFINET 222 Manual 08 2014 A5E01577426A RS AA 004 ...
Page 224: ...Correction sheet M200D PROFIBUS PROFINET 224 Manual 08 2014 A5E01577426A RS AA 004 ...
Page 232: ...Index M200D PROFIBUS PROFINET 232 Manual 08 2014 A5E01577426A RS AA 004 ...
Page 233: ......