Appendix
A.1 Data formats and data sets
M200D PROFIBUS/PROFINET
Manual, 08/2014, A5E01577426A/RS-AA/004
215
A.1.17
DS134 Read/write maintenance
Byte
Parameter
Range of values
Increment
Factory setting
Relevant for
Preamble
01
Coordination
0x21 Write via acyclic bus channel (PLC)
2
Reserved
0x00
3
Reserved
0x00
4 ... 7
Reserved
0x00
User data
8 ... 11
Maintenance timer - warning limit_1 0 … 4 294 967 295 s 1 s
946 080 000
(30 years)
All starters
12 ... 13
Maintenance timer - warning limit_2 0 … 4 294 967 295 s 1 s
946 080 000
(30 years)
All starters
A.1.18
DS165 Read/write comments
Components of a plant are provided with a unique identifier by the user when configuring the
plant. This identifier gives information about the installation location and the field of
application. The individual components are then provided locally with an appropriate label.
The motor starter supports electronic device identification. Data set 165 is used for this
purpose.
Byte
Data type
Meaning
0
ASCII char
First character
1
ASCII char
Second character
...
...
...
127
ASCII char
128. character
128
ASCII char
129. character
...
...
...
199
ASCII char
200. character
Summary of Contents for SIRIUS M200D
Page 2: ......
Page 90: ...Functions 3 22 Logbook M200D PROFIBUS PROFINET 90 Manual 08 2014 A5E01577426A RS AA 004 ...
Page 222: ...Appendix A 2 Order numbers M200D PROFIBUS PROFINET 222 Manual 08 2014 A5E01577426A RS AA 004 ...
Page 224: ...Correction sheet M200D PROFIBUS PROFINET 224 Manual 08 2014 A5E01577426A RS AA 004 ...
Page 232: ...Index M200D PROFIBUS PROFINET 232 Manual 08 2014 A5E01577426A RS AA 004 ...
Page 233: ......