Commissioning (software)
4.3 Performing an online configuration
SIMOTION D410
86
Commissioning Manual, 02/2012
4.3.2
Establishing the online connection
The procedure for an initial commissioning follows.
To perform an online configuration, you must establish an online connection to the
SIMOTION D410. In this case, no connection can yet be established to SINAMICS
Integrated. An appropriate message is output. Once the hardware configuration has been
loaded into the target device, an online connection to the SINAMICS Integrated is
established automatically. Proceed as follows:
1.
Save and compile the project.
2.
Establish an online connection.
3.
Select the SIMOTION D410 device in the Project Navigator.
4.
Use the "Download CPU / drive unit to target device" function to download the SIMOTION
D410 device to the target device. The connection to SINAMICS Integrated is activated
automatically.
You can now run the automatic configuration at SINAMICS Integrated. For details, refer to
the section titled Starting automatic configuration (Page 86).
Additional references
Further information about establishing an online connection to the PG/PC is contained in the
following documentation:
●
SIMOTION SCOUT Configuration Manual
●
SIMOTION SCOUT Online Help
●
In the FAQ for
SIMOTION Utilities & Applications
SIMOTION Utilities & Applications is provided as part of the SIMOTION SCOUT scope of
delivery.
4.3.3
Starting automatic configuration
Prerequisites
You activated the online connection to SINAMICS Integrated.