Maintenance and service
5.4 Performing a firmware and project update
SIMOTION D410
192
Commissioning Manual, 02/2012
If you are upgrading the firmware manually, proceed as follows:
1.
Select the SINAMICS component in the Project Navigator, for example, SINAMICS
Integrated.
2.
Double-click "Overview" in the project navigator.
The "SINAMICS_Integrated - Overview" dialog box opens with a list of available drive
objects.
3.
Click "Version Overview" to open the list of connected SINAMICS components.
4.
Go online and select the devices whose firmware you wish to update.
The list displays the current firmware version of the devices.
5.
Click "Firmware update" to download the new firmware to the devices. To do so, you
must select all components whose firmware is to be updated.
6.
When the firmware update is complete, switch the 24 V power supply off and on again.
The device is now ready for operation.
Note
The SINAMICS components must be configured for a firmware update to take place. The
firmware cannot be updated if the components are not programmed.
You can also update the firmware by means of the Expert list. Refer to the
SINAMICS
S120 Commissioning Manual for a description of this procedure.
5.4.5.4
Downloading the project to the target system
Once all the changes required for upgrading your project have been made, you must
download the project to the SIMOTION D410. You have recompiled the project and checked
it for consistency. Refer to section Save project, compile and check consistency (Page 183).
Prerequisite
The firmware required is located on the CompactFlash Card; for information, refer to the
section titled Update via CF card (Page 190).
Procedure
1.
Save and compile the project.
2.
Click "Connect to selected target systems" to establish a connection to the target system.
3.
Execute "Download project to target system" and then "Copy RAM to ROM" to download
the upgraded project to the CF card as well.
4.
Because of the automatic follow-up configuration in the SINAMICS Integrated drive, you
must now execute "Load CPU / drive unit to PG".
5.
Save the project.