Commissioning (software)
4.7 Setting up addresses and message frames
SIMOTION D410
114
Commissioning Manual, 02/2012
4.7
Setting up addresses and message frames
Overview
After all SINAMICS components have been configured, addresses must be determined for
the process data exchange between the drive and the controller.
This procedure depends on whether symbolic assignments are used.
●
With symbolic assignment , the addresses are determined automatically by the
engineering system; refer to section Setting up communication for symbolic assignment
(Page 114)
●
in the absence of symbolic assignment, addresses must be determined manually; refer to
section Message frame configuration (Page 115)
4.7.1
Setting up communication for symbolic assignment
You can set up communication for symbolic assignment using the following methods:
●
via the SCOUT menu (in the menu, call "Project" > "Set up communication for symbolic
assignment")
●
at "Download project to target system"
●
at "Save project and compile changes"
When you set up communication, the message frames, BICO interconnections, and
addresses are set up for the entire project.
See also