Description
2.5 History of active energy consumption
Equipment Manual, 09/2022, L1V30415168B-03
23
2.5
History of active energy consumption
Based on selected recordings of energy consumption over time, users can perform a targeted
analysis of their energy consumption for the purpose of optimizing their energy usage.
The power monitoring devices have a daily energy counter and a monthly energy counter.
•
The daily energy counter records the active energy in a ring buffer with a depth of 221
days.
•
The monthly energy counter records the active energy in a ring buffer with a depth of 25
months.
•
The annual energy counter records the active energy in a ring buffer with a depth of 7
years.
This function is available only in conjunction with communication interfaces.
You can find the list of available measuring values in chapters Active energy history with
Modbus function code 0x14 (Page 109).
2.6
Digital inputs and outputs
The PAC3200T has the following inputs/outputs:
•
1 digital input
•
1 digital output