Chapter
8
Operating Instructions
CLX490 Compact OMNI Scanner
8-2
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Troubleshooting
8.3
Error messages
The CLX outputs coded error message (number combinations) via the
auxiliary interface
only.
contains a list of the messages.
Displaying messages:
To display the messages on the PC, proceed as follows in CLV-Setup:
¾
Click
in the toolbar.
The Terminal Emulator is launched.
CLV-Setup logs the error messages automatically in a file (sys_msg.log).
8.3.1
CLX without external parameter memory
Message
Meaning
Possible cause
Remedy
"CLV SYS-Failure: xxx"
The CLX has diagnosed a
system error.
The "Device Ready" LED does
not light up or extinguishes.
The system is restarted.
Error key:
1
)
011
Data error (RAM)
012
Address error (RAM)
013
RAM to small
051
Speed out of tolerance
(mirror wheel)
061
Mirror interval out of
tolerance
071
Error: laser shutter
091to095Error: focus control
101to118Error: external parame-
ter memory
130
Amplifier error
131
Background profile
invalid
132
Center reading angle
RA 50 implausible
133
Brightness overflow
201to215DSP error
If the error occurs again after the
CLX is restarted, contact the SICK
Service department.
1) Deactivate the CAN interface
to suppress error numbers above
300 (not relevant in stand-alone
mode). To do so, upload the
parameter set from the CLX using
CLV-Setup, choose the CAN
I
NTERFACE
tab and deactivate the
function in the CAN I
NTERFACE
F
UNCTION
section.
Download the parameter set to
the CLX!
Table 8-1: Error messages output on the auxiliary interface